HRV - that the air handling unit, bringing heat energy into the building aquatech supplied with fresh outdoor air is heated exhaust air heat. Why modern house for mechanical ventilation system: Only RVs (ducted system) allows precise control of indoor ventilation; Building heat losses due to ventilation heat balance aquatech of a passive aquatech house is a very significant part. To minimize these losses, we use RVs. We expect out of the unit at least 80proc energy return at sealing the building aquatech (tightness aquatech is one of passivity aquatech conditions) RVs necessary to ensure adequate indoor air quality, control the air composition (amount of CO2 in the air) and humidity.
AHU assembled a technical room (boiler room call this neapsiverčia tongue because the boiler or the chimney no :)) even though the device is flat - it can be mounted above the suspended ceiling. We own hid his "industrial image suits us - and to show it will be much easier, not to mention the service. My first thought was it for approval in parallel allowance for the roof, but after examination of the condensate collection bath, it became clear that will be mounted horizontally. View technical room complex, a lot of tubes, but all fit. This is our system aquatech features: the two branches of ground heat exchanger, aquatech removing the hood duct, heat exchanger bypass duct.
In the northern wall of the building was cleared to the exhaust air box, it will be connected to the duct, which work off the air out of the unit is removed and the hood air inlet for the summer mode (when not required for heating, recycled air) air will be removed.
Existing Ductwork ground heat exchanger branches, procurement and disposal boxes were connected ducts. The disposal box is connected and the unit exhaust hood - two ducts on the left, right - the ground heat exchanger connection to the control valve. Later, she will get the drive:
Flexible ducts exchanger connected to the ventilation system, these ducts air supplied to the premises and removed exhaust air. The purpose of these ducts are insulated pipelines from the engine sound and vibration: aquatech
The valve is mounted on pick-up from the outside of the duct. Its purpose is to close the picking when it comes to the use of a heat exchanger and open land - some Zs unusable. It will be equipped with electric drive, which is derivative of this valve. The damper is mounted close to the wall as possible - thereby reducing heat loss through the duct:
This entry was posted aquatech in Uncategorized and tagged AHU air handling unit, amalva, C4 plus, DOMEKT, filter, HRV, Komfovent, condensate, air ducts, plate heat exchanger, cross flow heat exchanger, recue, recue 500PECFL-EC-4, the unit, RVs , valve, controller, ventilation, heat exchanger, ground heat exchanger. Bookmark the permalink.
06/02/2012 7:56 pm
Healthy, deserves some attention, but most likely not be implemented: no longer facade color, Tingey ordering :) another reason - and seizure, and disposal at the main facade, let yourself aquatech shine. And that shiny too well - people notice you, ask what and why :)
Siaip need to know only the facade of the RAL color and drove the Play paintshop. There, aquatech they are painted in powder coating according to your color code is given, the paint really well respected. Well, if you want others to pay attention to you, then of course, the color is very suitable for zinc;)
Vilius says:
Healthy Manta, a buried pipe is one of the types of Zs, just not write anything in the tube circulate air or glycol. Both options have their own pluses and minuses, but the most important is the depth - 1.5m is not bad, but would be much better 2-2.5m. Unfortunately, no such facilities design methodology is difficult to comment on the appropriate length of the system, but it is advisable to do a system of two branches, one branch running second rest (regenerates recovers ground temperature) after 4-6val changing places. aquatech Long and without interrupting the use of Zs for its efficiency decreases soil temperature - primer simply cold.
Welcome Mindaugaui, HRV is probably the smallest problem, aquatech it is mounted under the ceiling, the floor will not take place. Our technical room is approx 12m2, here everything will fit perfectly not only boiler, heat point, the unit but also a washer and dryer and a little pantry will remain.
Vilius says:
Gediminas Hello, Yes, there are conditions when the ground heat exchanger works "against the grain". Suddenly spring thaw: suppose today is -5C, the heat exchanger heats the air to + 5C, the exchanger is very pleased. Tomorrow aquatech the weather changed and we have įdienojus + 10C outside, as rubble after yesterday's work still chilly, the unit time accepting the + 10C will give only 6 + ... + 8C - instead Warms the air cools it. Then, when the outdoor air is warmer, we combine picking directly from the field. I have no doubt, in the evening and again gets cooler